Blood Glucose Meter Manufacturer
You are here: Home
NEUERO ENGINEERING INC. is an outstanding Manufacturer, Supplier and Exporter of Blood Glucose Meter, Blood Sugar Testing, with a factory in Taiwan. We supply and export persistently top quality Blood Glucose Monitoring System, Blood Glucose Meters, Blood Glucose Meter Kit, Blood Glucose Monitor, Blood Glucose Test Strip. We offer a product that is completely different to the conventional testing system that is currently available in the market. Our strips offer 3 independent blood glucose tests on a single strip while the accuracy and price remains the same as major brands.
We are committed to continuous improvement of our manufacturing processes and work environment through innovation, creativity and team work. As a result of focus and employee synergy, we were able to create products that match the quality of major brands and compliant with varies international standards. At the same time, we are extremely competitive in price. If you are interested in any of our products, please feel free to contact us.

Blood Glucose Meter

Our goal is to achieve customer satisfaction through providing high quality

Blood Glucose Meter, Blood Sugar Testing

at a very competitive price. It is our focus to manufacture products that satisfy the needs and requirements of our clients.
At present, the majority of people with diabetes have used the blood glucose meter, while Blood Glucose Monitoring System is not applicable in the screening or diagnosis of diabetes. On the other hand Blood Glucose Meters is an important tool to assess diet, exercise and drug treatment in order to achieve the important goal of glucose control. Especially for the patients who are taking insulin or oral hypoglycemic, it is necessary to use Blood Glucose Test Monitor to monitor their blood sugar not go to too high or too low.
In the clinic, it is found that the wrong operation and the technical errors in the Blood Sugar Testing which are resulting from patients who are willing to self-monitor blood sugar can be perfectly corrected by the brochures or the relevant technical personnel or the professional doctors.
However, based on 2009 American Diabetes Association recommends diabetes blood glucose control goals are: fasting blood glucose between 90 ~ 130 mg / dL, two hours after a meal blood sugar is less than 180mg/dL and glycosylated serum protein is less than 7% .Its sample is the blood of the plasma does not contain red blood cells, non-portable Blood Glucose Meter Kit need to use the fingertip capillary blood.
The correct interpretation of the difference, perhaps because of commercial considerations or lack of professionalism, they have been intentionally or unintentionally ignored. Therefore, the accuracy of portable blood glucose meter and the numerical representation are always concern for some diabetics. Part of the diabetes may also be misled; therefore, it fails to reach optimal blood glucose control targets.
Generally speaking, fasting capillary blood glucose is only slightly higher than the venous blood glucose of about 2 ~ 3 mg / dL, as a result of differences in the same Hsiao Ke. After dinner, when capillary blood glucose may be higher than the venous blood glucose up to 20 ~ 70 mg / dL, the hospital medical testing in patients with elbow forearm venous blood obtained after centrifugation as "venous plasma," the use of portable blood glucose meters patient fingertip capillary blood obtained from the "capillary whole blood", plasma glucose value was higher than the whole blood glucose value of about 10 ~ 15%.
First understand the concept of a different time (fasting or after a meal) in different parts of the (arterial, capillary or venous) blood samples collected from different nature (including mined by capillary or venous whole blood red blood cells, blood plasma after centrifugation does not contain red blood cells) obtained the value of both the difference in blood glucose. The conclusions of the above the technical level, the concept of diabetes should be as follows: using blood glucose meter blood glucose values measured at fasting with roughly 10 ~ 15%, minus the rough at dinner time 17 ~ 63 mg / dL, values obtained with the the hospital may be more close to the measured blood sugar.
Portable blood glucose meters available in the market variety, detection principles are not the same, some of the brand advertised as a blood glucose value has been fixed. However, because changes due to too much, even if the exclusion operation and environmental factors, the patient itself is the blood hematocrit, hypotension, hypoxia, high triglycerides, high or low blood sugar condition, still could lead to deviation of Blood Glucose Monitor values.
The use of portable blood glucose meter diabetes blood glucose self-monitoring of blood glucose control for the achievement of objectives and to avoid low blood sugar occurs extremely helpful. But it must be regularly measured value of blood glucose meters and hospital laboratory values than the right to amend in order to avoid misjudgment of blood glucose occurrences.
How to analyze the test results of Blood Glucose Meter?
Self-monitoring of blood glucose in diabetes treatment in a major test content. Portable blood glucose sensor (referred to as blood glucose meters) is an essential tool of Blood Sugar Testing.
At present, the market blood glucose meters at least 20 kinds of models. Despite all the different blood glucose meter manufacturers and different models, they share the following characteristics: detection of capillary blood, and detection principle is similar to using dipstick testing, in order to dry the main power, light weight, small size, easy to carry, instrument calibration simple procedure, test results were affected by many factors and so on.
1. Improper operation: blood glucose meter test results the most important reason is the large variation of the user's improper operation, such as the drop of blood the size of the drop of blood in the test strip on the location determination process does not meet the requirements.
2. Hematocrit: anemia or polycythemia can affect blood glucose meter test results. Anemia so that self-blood glucose test results than the actual value is high; polycythemia is the value of its measured value is lower than the actual. Every change in hematocrit is usually 10% of the measured values of different blood glucose meters can produce 4% ~ 30% of the impact.
3. Blood Glucose Test Strip question: more than shelf-life or keeping improper also affect the test results. Affect the blood glucose meter accuracy and precision of the factors that self-monitoring of blood glucose effectiveness will depend on the accuracy and precision of blood glucose meters. Accuracy of test results refers to the closeness of the real value; accuracy refers to the testing repeatability. Generally strictly controlled operating conditions and steps of the circumstances, the blood glucose meter accuracy and precision to achieve the standards (generally refers to the coefficient of variation 2% ~ 5%). However, if the following conditions exist, blood glucose meter accuracy and precision will be affected.
In addition, the patient's mood, ambient temperature and humidity, hypotension, hypoxia, and blood triglyceride levels and other factors will affect the blood glucose meter test results. Clearly, the blood glucose meter accuracy and precision of the performance by the apparatus, and the user's operation of the quality of technical decisions. The former two alternative cases, the user's operative technique becomes particularly important. Medical workers and vendors on behalf of blood glucose meters blood glucose meters have the responsibility of the users of technical training.
How to determine the accuracy and precision of blood glucose meters?
Given the current models on the market blood glucose meters wide variety, the larger variation between the test results, it can only be used for blood glucose monitoring cannot be used for diagnosis and screening of diabetes.
United States Institute of Clinical Biochemistry (NACB) and the American Diabetes Association (ADA) recommended the use of portable blood glucose meter blood glucose in patients must be regularly monitored blood glucose results and the results of the inspection department of the hospital as control to assess the value of their detection accuracy. With the laboratory results for blood glucose control should pay attention to: to do glucose tolerance or postprandial blood glucose test, the blood glucose meters blood glucose measured was significantly higher than hospital laboratories biochemical analyzer measured blood glucose value (an average of 1.7 cents Mount / l ), but no significant difference between fasting (a difference of only 0.1 cents Mount / l).